Gow Mac Gc Manual

Series 590 DID Gas Chromatograph Detector The Series 590 DID GC contains a single, GOW-MAC® discharge ionization detector (DID) which is non-radioactive, universal, and concentration dependent. The detector uses an electrical discharge in helium to generate high energy UV photons and metastable helium which ionizes all compounds except helium.

Model Series 590 - Discharge Ionization Detector (DID) Gas Chromatograph

Gow Mac Gc Manual Pdf

From Instruments - Gas Chromatographs

Gow mac gc manual download

The Series 590 Gas Chromatograph features our patented Discharge Ionization Detector (DID) which permits analysis of trace gas impurities in the part per billion (ppb) range. Manufacturers of UHP specialty, electronic and bulk industrial gases are successfully using the Series 590 DID GC to analyze gases for ppb level of contamination.

  • Most popular related searches

Product Overview

Gow Mac Gc Manual Downloads

Mac

Each Series 590 GC is custom built to a particular application. Contact us to discuss the details or your specific requirements.

  • Discharge Ionization Detector (DID) — non-selective, non-radioactive, universal and concentration dependent
  • Detector sensitivity: < 10 ppb CH4
  • Detector linearity: > 105
  • Dynamic range of < 5 ppb to < 1% by volume
  • High analytical precision: ± 1% full scale
  • Output: 4-20 mA (optional); 0-1 mV
  • Helium purged housing eliminates system contamination and increases system sensitivity
  • Bellows type metering valves for independent flow control of column carrier gases and detector discharge gas
  • Choice of standard or corrosion resistant system
  • Installation: bench or 19” rack mount
  • On-line monitoring and valve manipulation by software or linking workstation
  • Power: 120-240 V, 50-60 Hz

Contact supplier

Model Series 580 - Gas Chromatograph

From Instruments - Gas Chromatographs

The Series 580 Gas Chromatograph sets the standard for reliable performance in a wide range of applications. So impressive has the performance of this GC been, that many 580 users refer to it as 'The Workhorse' instrument of their laboratory. The Series 580 GC can be customized to fit the exact requirements your application requires, utilizing either a TCD, FID, DID or PID detector.

Gow Mac Gc Manual Free

  • Most popular related searches

Gow Mac Gc Manual Downloads

Features

Gow Mac 400 Manual

  • Isothermal Operation
  • Detectors: TCD, FID, DID, or PID
  • Direct On-Column Injection or Gas Sample Valve: packed, capillary — split/splitless
  • Single or Dual Column
  • Accommodates 1/8” or 1/4” o.d. metal, 6 mm glass, or capillary columns
  • Column temperature range: ambient to 400 °C
  • Column oven temperature protection circuit
  • Readout: 3-1/2 digit LED digital display
  • Independent Temperature Controls for Column Oven, Detector, Injection Ports
  • On-line monitoring and valve manipulation by software or linking workstation
  • Microscale Compatible: heated, threaded exit ports, (optional — TCD only)
  • Signal Amplifier, x10 (TCD — optional)
  • Choice of standard or corrosion resistant system
  • Installation: bench or 19” rack mount
  • Power: 110-220 V, 50-60 Hz